Stacks Image 354

MALCOM DS-03 DIP TESTER

The Malcom DS-03 Dip Tester dual wave measurement system. Attain vital soldering performance information with just one device.
FEATURES & BENEFITS:
  • The self contained DS-03 rides along the conveyor like a PCB.
  • Measures the record's maximum PCB topside preheat temperature.
  • Confirms flux and solder levels.
  • Measures and records the maximum temperature and dwell times of both solder waves.
  • Optional printer unit available.
SPECIFICATIONS:
GENERAL SPECIFICATIONS
ITEM SPECIFICATION
Cold Contact Point Compensation Automatic compensation w/ platinum temperature measuring resistor
Ambient Temperature 5 min. or less is OK at ambient temperature of 120°C
Battery (1) S-006P 9V DC
Usable Time More than 10 continuous hours
Life of Sensor Mounting Plate More than 5,000 times at soldering temperature of 250°C and dip time of 5 sec.
Outer Dimensions (mm) 94 (W) x 230 (D) x 51 (H)
Weight 840g (w/o battery)
MEASUREMENT DATA SPECIFICATIONS
ITEM SENSOR DISPLAY METHOD MEASUREMENT RANGE ACCURACY / CONTENTS
Soldering Temperature K Sheath
Thermocouple
Digital LCD 3-digit 0 ~ 300°C ± 2°C
Temperature on the
Topside of Board
K Tehermocouple 50 ~ 300°C ± 2°C
Dip Time Electrode 0 ~ 10.0 sec. ± 0.2 sec.
Flux Dryness Electrode (resistance) LED
Red = NG
Green = OK
10KΩ - 5MΩ 2Φ electrode intervals of 4mm
Flux Height Electrode With reference to underside of board 0 - 6mm Scale resolution 1mm
Solder Height Electrode

* Specifications subject to change without notice.


Stacks Image 355

MALCOM DS-05 DIP TESTER

The Malcom DS-05 Dip Tester measures vital soldering performance information using external measuring points on your PCB.
FEATURES & BENEFITS:
  • The tester enables the preheat and solder temperature to be measured at any given locations.
  • With up to 3 dip time sensor points, you can reliably verify the dip time.
  • A conveyor speed measurement feature is added, enabling the reliability of your soldering equipment.
SPECIFICATIONS:
GENERAL SPECIFICATIONS
ITEM SPECIFICATION
Cold Contact Point Compensation Automatic compensation w/ platinum temperature measuring resistor
Battery (4) AA Cells
Usable Time More than 200 continuous hours
Outer Dimensions (mm) 92 (W) x 195 (D) x 50 (H)
Weight 840g (w/o battery)
MEASUREMENT DATA SPECIFICATIONS
ITEM SENSOR DISPLAY METHOD MEASUREMENT RANGE ACCURACY / CONTENTS
Soldering Temperature K Sheath
Thermocouple
Digital LCD 3-digit 0 ~ 300°C ± 2°C
Temperature on the
Underside of Board
K Tehermocouple 50 ~ 300°C ± 2°C
Dip Time Electrode 0 ~ 10.0 sec. ± 0.2 sec.
Conveyor Speed Electrode 0.1 ~ 9.9 m/min ± 0.05 m/min